[Delivery Example] Pre-cooling tower + Venturi + Demister tower + 2 packing towers
Acetic acid gas is removed from 25,000 ppm to below 1 ppm, and fume-like sublimates are reduced from 5 g/Nm³ to below 0.1 g/Nm³!
We would like to introduce a case study of the delivery of a pre-cooling tower + Venturi + demister tower + two filling towers conducted by E-Techno. The gas-liquid contact is achieved through water (circulation + supply) for cooling, fume removal, and the injection of caustic soda aqueous solution for pH control to absorb acetic acid. The target substance, acetic acid gas, was reduced from 25,000 ppm to below 1 ppm, and fume-like sublimates were reduced from 5 g/Nm³ to below 0.1 g/Nm³. [Case Study] ■ Industry of Delivery: Chemical ■ Equipment Designed and Installed: Pre-cooling tower + Venturi + demister tower + two filling towers ■ Designed Removal Rate - Acetic Acid Gas: 25,000 ppm to below 1 ppm - Fume-like Sublimates: 5 g/Nm³ to below 0.1 g/Nm³ ■ Packing Material: Hyrex 200PP 2000H x 2 ■ Material: Main body made of SUS304 and corrosion-resistant FRP *For more details, please refer to the PDF document or feel free to contact us.
- Company:イーテクノ 本社